Hall 04 · cold aisle drift

00%
Cluster load
18.0°C
Aisle intake
8000 nodes · 32 racks · 1152 indicators
Idle0 – 30%
Serving30 – 75%
Hot nodeabove 75%
Hall 04 · 62% racked

Put your hardware
in a hall that stays cold.

NORTHGRID is a carrier-neutral colocation hall on Ironvale Road. Single units up to full 47U racks, A and B feeds from separate boards, closed cold aisle, and cross-connects patched within one working day.

32racks in hall 04
2.4MWutility feed
99.982%power uptime, 12 months
drag to orbit · scroll to zoom
Space

From one unit to a full rack,
priced the same way for everyone.

Every line below is the monthly price plus the power it includes. Nothing is quoted per request: if you need more draw than the line carries, the extra kilowatt is metered at a published rate.

Contracts run 12, 24 or 36 months. Month-to-month is available on single units and quarter racks at a 15% premium. Installation windows are booked in two-hour slots, seven days a week.

Single unit · 1UShared rack

1U of 470.3 kW included1 Gb port

A single server in a shared, locked rack in row B. Front and rear access by appointment, one power feed with a metered second feed available.

$95per month

Quarter rack · 10U

10U lockable1.2 kW includedA + B feeds

Ten units behind your own perforated door inside a shared cabinet. Two PDU outlets per feed, one cross-connect included in the first month.

$620per month

Half rack · 21UMost taken

21U lockable2.5 kW includedA + B feeds

The smallest footprint that still takes a top-of-rack switch, a firewall pair and a tape unit without fighting for depth. 1070 mm cabinets throughout.

$1,140per month

Full rack · 47U

47U private5 kW includedA + B feeds

A cabinet of your own in row A or row B, keyed to your staff only. Blanking panels, brush strips and cable management are fitted before handover.

$2,150per month

Cross-connect

Single mode or copperMeet-me roomPatched in 1 day

A fibre or copper pair from your cabinet to any carrier, exchange port or another tenant in the building. Ordered in the portal, patched by our staff.

$180setup, then $45/mo

Transit & traffic

Blended, two upstreams95th percentileBurst allowed

Committed bandwidth billed at the 95th percentile, bursting to the full port. A 10 GbE port is $340 per month; a 1 GbE port is included with half and full racks.

$2.40per Mbps / month
Metered power above the included draw: $0.21 per kWh, read from the cabinet PDU and shown in the portal every hour. Remote hands are $75 per hour in 15-minute increments, free for the first 30 minutes each month.
Network

Carrier-neutral fabric:
every node has a second path.

The diagram below is live. Nodes drift, and a link is drawn whenever two of them come inside the threshold distance — which is exactly how a mesh behaves when a path is withdrawn and the neighbours pick the traffic up. Drag a pointer or a finger across it to pull a region together.

Two independent meet-me rooms, seven upstream carriers, one public exchange port. No carrier owns the building, so nothing is bundled with the floor space.
Fabric view · 0 active links
0 nodes in view
drag across to gather a region

Upstreams in the meet-me room

  • Northline Telecom100GMMR A · port 04 · since 2019
  • Vantage Fibre100GMMR B · port 11 · since 2021
  • Calder Metro Dark2×10GMMR A · dark pair to the city ring
  • Ironvale IX40Gpublic exchange port, 214 peers
  • Four regional ISPs10G eachreachable as a cross-connect
0.6 msto the city ring
7upstream carriers
214peers on the exchange
< 1 daycross-connect patched
Power & cooling

Two feeds, two boards,
one cold aisle.

Nothing in the hall is fed from a single path. A and B come from separate transformers, separate UPS strings and separate distribution boards, and we test the transfer under load on a published schedule.

Cold aisle 04 is closed top and end, held at 18 °C intake and 41% relative humidity. Return air leaves the hot aisle at 31 °C.
Utility

2.4 MW feed

Two 11 kV incomers from different substations on the Ironvale loop, each able to carry the hall alone. Switching is automatic and logged.

Ride-through

UPS 2N, 11 min

Two independent UPS strings, each sized for the whole load. Battery runtime is eleven minutes at full draw — four times what the generators need to take over.

Standby

Diesel N+1

Three generators for two halls, 72 hours of fuel on site with a refuelling contract on call. Started under load on the first Tuesday of each month.

Cooling

N+1 chilled water

Four in-row units on a closed cold aisle, any one of which can be pulled for service without moving the intake temperature past 20 °C.

Per cabinet

Up to 11 kW

Standard cabinets take 5 kW without special handling. Above that we move you to the high-density row and fit blanking and containment to match.

Metering

Hourly PDU reads

Every outlet strip reports current per phase. Your portal shows the hourly figure that the invoice is built from — no estimates, no reconciliation.

Fire

Inert gas, two zones

Aspirating smoke detection under the floor and at ceiling level, inert gas release split by zone so one hall never dumps into the other.

Uptime & load

Fifty-two weeks of the hall,
drawn as a relief.

One column per day: its height and colour are the peak load the hall carried that day, and a flat tile means the day passed with nothing above the quiet baseline. The two dips you can find are the scheduled transfer tests.

Hover or touch a column to read the day. Figures are the invented record of a demo hall — they are consistent with each other, not with any real facility.
Week 26 · Thursday peak load 58% · no incident
52 weeks · 7 days · 364 columns
quiet peak
Power

99.982%

Measured at the cabinet strip across twelve months, both feeds counted separately.

Network

99.995%

Blended transit reachability from an outside probe, five-minute samples.

Cooling

20.4 °C

Warmest intake reading of the year, recorded during the July in-row service.

Incidents

2

Both on a single upstream, both absorbed by the second path. No customer impact.

Access

Four levels of access,
and a record of every door.

You name the people; we issue the level. A badge opens only the doors its level carries, and every swipe is written to a log you can export from the portal for the last 24 months.

Two-person rule on the plant rooms. Camera coverage of every aisle and every door, held 90 days. Staffed reception 07:00–20:00, security on site around the clock.
L1

Escorted visit

Booked at least two hours ahead. A member of our staff meets you at reception, walks you to the cabinet and stays with you. Photo ID is checked and held at the desk.

Guests · auditors
07:00–20:00
L2

Badge to your own aisle

Badge plus PIN at the mantrap, badge at the aisle door, key at the cabinet. No access to plant rooms, meet-me rooms or another tenant's row.

Named engineers
24 / 7
L3

Meet-me room and patching

Adds the two meet-me rooms during working hours, for tenants who terminate their own carrier circuits. Patch changes are logged against your ticket.

Network staff
08:00–19:00
L4

Remote hands, on your behalf

No badge at all: you raise a ticket and our technician does the work, with a photo of the front and rear of the unit attached to the ticket before it closes.

Our technicians
24 / 7
Service level

The agreement, in the
four numbers that pay out.

We publish the commitment and the credit together, because a number without a credit behind it is a marketing line. Credits are applied to the next invoice automatically once the incident report is closed.

Measured per calendar month on the affected service only. Scheduled maintenance is announced ten days ahead and is excluded, as is anything inside your own hardware.
100% Power at the strip Both feeds. A single feed failing is not an outage while the other carries you.
99.99% Network reachability Blended transit, measured from three outside probes at five-minute samples.
18–27 °C Cold aisle intake Held at the cabinet door, not at the room sensor. Logged every minute.
15 min Remote hands response From ticket to a technician standing at your cabinet, at any hour.
If the month falls belowRoughlyCredit on the next invoice
99.99% networkover 4 minutes down5%
99.9% networkover 43 minutes down15%
99.0% networkover 7 hours down30%
Power lost at both feedsany duration50%
Intake above 27 °C for an hourper occurrence10%
The site

A print works that already had
the power and the floor.

210 Ironvale Road was a newspaper print hall until 2014: a slab rated for rotary presses, two 11 kV incomers already in the yard, and a ceiling high enough for containment without cutting into the roof. We took the shell in 2016 and spent two years putting a data hall inside it rather than around it.

Hall 04 opened in 2019 with sixteen cabinets. It now runs thirty-two, with hall 05 framed out next door and due to take its first row next spring. The operations team is eleven people, six of whom have been here since the first rack went in.

2016Site taken over
32Cabinets in hall 04
11People on the operations team
4.9From 68 tenant reviews

We do not sell a tier badge. We publish the feed diagram, the transfer test schedule and the intake log, and we let an engineer read them before signing anything. Everyone who has asked for that has stayed.

Marek Halloran · hall operations
What we do not do

No managed servers

We are the floor, the power, the cooling and the cross-connect. We do not sell virtual machines, backup or managed operating systems, so we are never competing with the company renting the rack next to yours.

Moving in

Two weeks from signature

Cabinet keyed and powered within five working days, cross-connects patched inside one day of the order, and a loading bay slot with a pallet lift booked for the day your hardware arrives.

Tenants

What the engineers who
hold the keys say.

Three of sixty-eight reviews left in the tenant portal. Invented people for an invented hall.
★★★★★

We moved eleven racks out of a building where the A and B feeds turned out to share one board. Here I was handed the single-line diagram before I asked for it. The transfer test in March did exactly what the schedule said it would.

DR
Devan RoyeInfrastructure lead · 11 racks
★★★★★

Cross-connect to a second carrier ordered at 16:00, patched and lit by 11:00 the next morning, with the port and the fibre id in the ticket. That is the part most places quietly take three weeks over.

IS
Iliana SarkisNetwork architect · half rack
★★★★☆

Remote hands have never taken more than twenty minutes, even at three in the morning. My only complaint is the loading bay: one lift for two halls means you book the slot early on a delivery day.

TO
Tomas OvendenPlatform engineer · quarter rack
Visit

Reception has hours.
Your cabinet does not.

Tenants at level 2 and above walk in at any hour with a badge and a PIN. The office hours below are for tours, deliveries, contract work and anyone who needs an escort.

Loading bay on the Feldspar Lane side, pallet lift to hall level, booked in two-hour slots. Parking for six vehicles inside the fence.

Office and reception

Monday07:00 – 20:00
Tuesday07:00 – 20:00
Wednesday07:00 – 20:00
Thursday07:00 – 20:00
Friday07:00 – 20:00
Saturday09:00 – 16:00
Sundayescorted visits by arrangement
Hall access 24 / 7 for badged tenants Security is on site around the clock. Out of office hours the mantrap is the only way in, and the log shows who used it.

Find us

Request capacity

Tell us the draw and
the date. We reply with a plan.

No sales call before the numbers. You get the available cabinets, the feed they sit on and a dated installation window.

  • Answered by an engineer, not a sales desk, within one working day.
  • Single-line diagram and transfer test schedule sent before any contract.
  • Tour of hall 04 and the meet-me rooms, booked at a time you name.
  • Nothing leaves this page — the form is part of a demo concept.
Please give a name we can address the reply to.
Tell us which company the cabinet is for.
That address does not look complete.
Pick the footprint you are planning for.
An estimate is fine — pick the closest band.
Choose a date from today onwards.

Request logged

We have your request. An engineer will reply within one working day.

Reference NG-0000
Nothing was sent — this is a demo concept.
Questions

Asked before the first tour.

Anything not here, ask the operations team directly: noc@northgrid.systems.
Can I bring my own cabinet?
Yes, for a full-rack contract, as long as it is 600 mm wide, no deeper than 1200 mm and takes our containment blanking at the top. We fit the brush strips and the PDU rails so the aisle seal stays intact. A cabinet of ours is included in the price, so bringing your own does not reduce it.
What happens if one power feed fails?
Nothing you notice, provided your hardware is on both. Dual-corded units keep running on the surviving feed; single-corded units should sit behind an automatic transfer switch, which we will fit on request for $210. We publish the transfer test schedule ten days ahead so you can watch your own kit ride it out.
How quickly can a cross-connect be ordered and lit?
Order it in the portal and our staff patch it the same working day, or the next morning for anything raised after 17:00. The ticket closes with the port, the fibre identifier and a photo of both ends. The first cross-connect is free for quarter racks and above during the first month.
Do you take a single server, or is there a minimum?
A single unit at $95 per month is a real product, not a courtesy. It sits in a shared locked rack in row B with 0.3 kW included and a 1 Gb port. You can move up to a quarter or half rack at any point in the contract and we credit the unused part of the month across.